After elimination of the fault, the buscoupler can only be set to the normal working condition by another POWER ON sequence.

The green I/O LED flashes when accessing the I/O modules internal data channels. After being switched on, the buscoupler queries the configuration of the bus modules but does not carry out a data exchange with the I/O modules. This means that the red I/O LED will extinguish after a faultless startup. The green I/O LED will indicate when data is being exchanged by the Interbus network.

Status and error diagnostics:

The fieldbus LEDs show the state of the bus system. The functions of Interbus S are shown by the LEDs „READY“, „BA“, „RC“ and „RD“.

READY

BA

RC

RD

Meaning

Help

 

 

 

 

 

 

on

off

off

off

Buscoupler ready

 

 

 

 

 

 

 

on

on

off

off

Fieldbus active; data exchange

 

 

 

 

 

 

 

on

off

on

off

incoming connection established

 

 

 

 

 

 

 

on

off

off

on

Field bus off

search error in

 

 

 

 

error in cable or master

cable or master

off

off

off

off

no function ; no voltage

 

 

 

 

 

 

 

Table 7: Diagnostic LEDs - fieldbus

INTERBUS S / Startup

24

:$*2Ç, 2Ç6<67(0

7 General conditions

This chapter describes the general conditions for error-free running of the

:$*2Ç, 2Ç6<67(0

7.1Transporting and storing conditions

The following declarations concern modules which are transported and stored in the original package.

Condition

Free fall

Temperature

Relative humidity

allowed values

≤ 1m

-40° to +70° C

5 to 95% (without condensation)

7.2 Mechanical and climatic conditions

The modules of the :$*2Ç, 2Ç6<67(0 are not allowed to be operated without taking suitable actions

-in places with strong conditions e.g. very dusty rooms or corroding atmosphere

-in place with high concentrations of ionisation

The temperature should be in a range between 0° C and +55° C. The relative humidity should be in a range of 5 to 95% (without condensation).

The modules should be placed horizontal for better heat dissipation.

The concentration of SO2 must be below 25 ppm with a relative humidity of < 75%. The concentration of H2S must be below 10 ppm with the same humidity.

The mechanical conditions are given as sinusoidal oscillations.

Frequency range (Hz)

continuous

sometimes

10

≤ f < 57

0.0375 mm amplitude

0.075mm amplitude

57

≤ f ≤ 150

0.5 g constant acceleration

1 g constant acceleration

For stronger impulses and oscillations, the acceleration and the amplitude should be reduced by suitable actions. The following table shows the type of test for the mechanical conditions.

INTERBUS / General conditions

25

:$*2Ç, 2Ç6<67(0

Test for

Oscillations

Impulse

Test sequence

Test for oscillations IEC 68, part 2-6

Test for impulses IEC 68, part 2-27

Remarks

Type of oscillation: sweep with a rate of change of 1 octave per minute

10 Hz ≤ f < 57 Hz, const. amplitude 0,075mm

57 Hz ≤ f ≤ 150 Hz, const. acceleration

1 g

period of oscillation: 10

sweep per axis in each of the 3 vertical axes

Type of impulse: half sinusoidal Intensity of impulses: 15 g peak value, 11 ms maintenance time

route of impulses: 2 impulses in each of the 3 vertical axes

7.3Class of protection and degree of protection

The class of protection is IP2X (IEC 529), i.e. protection against touch with a standard test object. There is also protection against solid bodies greater than 12 mm. There is no special protection against water.

INTERBUS / General conditions

26

:$*2Ç, 2Ç6<67(0

7.4Electromagnetic compatibility

Method of measurement

Interference with narrow-band conducted disturbance

Interference with impulse groups

Discharge of static electricity

Interference with electromagnetic fields

Interference field strength

Disturbance

EN 50082-2, A

EN 50082-2, B

EN 50082-2, B

EN 50082-2, A

EN 55011

These requests for electromagnetic compatibility are fulfilled by all modules of :$*2Ç, 2Ç6<67(0 (except for 750-630 and 750-631).

7.5Power supply

If non-stabilized power supply is used for the supply of the buscoupler, it must be

stabilized by a capacity ( 200 µF per 1 A load current).

For the :$*2Ç, 2Ç6<67(0 a filter module has been developed (288-824).

This module serves as a filter module for non-stabilized 24 V DC power supplies if the specified voltage deviation is not met.

Reasons for the deviations may be voltage jumps in the primary circuit, overloads in the secondary circuit or the switching of undampened inductances and capacitances.

7.6Certificates

The modules of :$*2Ç, 2Ç6<67(0 have passed the conformance test of UL. Look for listing mark on product.

The Profibus coupler 750-301 and 750-303 are certified of PNO with Z00241 and Z00242.

The Interbus coupler 750-304 has passed the relevant tests in accordance with the Interbus conformance requirements (number 111).

The DeviceNet coupler 750-306 has succesfully passed through the conformance test of Open DeviceNet Vendors Association Europe.

INTERBUS / General conditions

27

:$*2Ç, 2Ç6<67(0