Page 166​

 

DICOM PS3.16 2020a - Content Mapping Resource​

 

 

 

NL​ Rel with Parent​ VT​

Concept Name​

VM​

Req​

Condition​

Value Set​

 

 

 

 

 

 

Type​

 

Constraint​

3​

>​

HAS​

PNAME​

BCID7453“PerformingRoles”​ 1-n​

U​

 

 

 

 

PROPERTIES​

 

 

 

 

 

 

4​

>​

HAS​

NUM​

EV (121128, DCM,​

1​

U​

 

 

 

 

PROPERTIES​

 

"Procedure Action Duration")​

 

 

 

 

5​

>​

 

INCLUDE​ DTID 3010 “Log Entry​

1​

U​

 

 

 

 

 

 

Qualifiers”​

 

 

 

 

6​

>​

HAS​

UIDREF​

EV (121126, DCM,​

 

 

PROPERTIES​

 

"Performed Procedure Step​

 

 

 

 

SOP Instance UID")​

7​

>​

HAS​

UIDREF​

EV (121127, DCM,​

 

 

PROPERTIES​

 

"Performed Procedure Step​

 

 

 

 

SOP Class UID")​

Content Item Descriptions​

1​ MC​ IFF a Performed​ Procedure Step SOP​ Class is used to​ provide status of the​ Procedure Step​

1​ MC​ IFF a Performed​ Procedure Step SOP​ Class is used to​ provide status of the​ Procedure Step​

Row 2​

The value of the Procedure Action ID shall be uniquely associated with the step or action within the context​

 

of the Study, and may be used to associate various Procedure Log entries with the step or action.​

Row 3​

May be used to record the identity of staff roles for the purpose of this Procedure Action, which may differ​

 

from their roles in the procedure as a whole.​

TID 3101 Image Acquisition​

The Image Acquisition Template allows recording of the essential parameters of a digital image acquired during the procedure.​

Type:​

Extensible​

Order:​

Significant​

Root:​

No​

Table TID 3101. Image Acquisition​

 

NL​

Rel with Parent​ VT​

Concept Name​

VM​

Req​ Condition​Value Set Constraint​

 

 

 

 

 

 

Type​

 

1​

 

 

IMAGE​

EV (121138, DCM, "Image​

1​

M​

 

 

 

 

 

Acquired")​

 

 

 

2​

>​

HAS ACQ​

UIDREF​

EV (112002, DCM, "Series​

1​

M​

 

 

 

CONTEXT​

 

Instance UID")​

 

 

 

3​

>​

HAS ACQ​

CODE​

EV (121139, DCM,​

1​

M​

DCID 29 “Acquisition​

 

 

CONTEXT​

 

"Modality")​

 

 

Modality”​

 

 

 

 

 

 

 

Derived from referenced​

 

 

 

 

 

 

 

image SOP Instance​

 

 

 

 

 

 

 

attribute (0008,0060)​

4​

>​

HAS​

NUM​

EV (121140, DCM, "Number​ 1​

U​

 

 

 

PROPERTIES​

 

of Frames")​

 

 

 

5​

>​

HAS​

TEXT​

EV (121141, DCM, "Image​

1​

U​

From referenced image​

 

 

PROPERTIES​

 

Type")​

 

 

SOP Instance attribute​

 

 

 

 

 

 

 

(0008,0008)​

6​

>​

HAS ACQ​

NUM​

EV (112011, DCM,​

1​

U​

UNITS = EV (deg,​

 

 

CONTEXT​

 

"Positioner Primary Angle")​

 

 

UCUM, "deg")​

- Standard -​

 

 

 

DICOM PS3.16 2020a - Content Mapping Resource​

Page 167​

 

NL​

Rel with Parent​ VT​

Concept Name​

VM​

Req​ Condition​Value Set Constraint​

 

 

 

 

 

 

Type​

 

7​

>​

HAS ACQ​

NUM​

EV (112012, DCM,​

1​

U​

UNITS = EV (deg,​

 

 

CONTEXT​

 

"Positioner Secondary​

 

 

UCUM, "deg")​

 

 

 

 

Angle")​

 

 

 

8​

>​

 

INCLUDE​ DTID 3010 “Log Entry​

1​

U​

 

 

 

 

 

Qualifiers”​

 

 

 

TID 3102 Waveform Acquisition​

TheWaveformAcquisitionTemplateallowsrecordingoftheessentialparametersofadigitalwaveformacquiredduringtheprocedure.​

Type:​

Extensible​

Order:​

Significant​

Root:​

No​

 

Table TID 3102. Waveform Acquisition​

 

NL​ Rel with Parent​ VT​

Concept Name​

VM​

Req​ Condition​Value Set Constraint​

 

 

 

 

 

 

Type​

 

1​

 

 

WAVEFORM​EV (121143, DCM,​

1​

M​

 

 

 

 

 

"Waveform Acquired")​

 

 

 

2​

>​

HAS ACQ​

CODE​

EV (121139, DCM,​

1​

M​

DCID 29 “Acquisition​

 

 

CONTEXT​

 

"Modality")​

 

 

Modality”​

 

 

 

 

 

 

 

Derivedfromreferenced​

 

 

 

 

 

 

 

waveformSOPInstance​

 

 

 

 

 

 

 

attribute (0008,0060)​

3​

>​

HAS ACQ​

NUM​

EV (121142, DCM,​

1​

U​

 

 

 

CONTEXT​

 

"Acquisition Duration")​

 

 

 

4​

>​

 

INCLUDE​

DTID 3010 “Log Entry​

1​

U​

 

 

 

 

 

Qualifiers”​

 

 

 

TID 3103 Referenced Object​

TheReferencedObjectTemplateallowsreferencetomeasurementorreportobjects,suchaspriormedicalreports,laboratoryresults,​ hemodynamic measurement reports, or quantitative analysis reports.​

Type:​

Extensible​

Order:​

Significant​

Root:​

No​

 

Table TID 3103. Referenced Object​

 

NL​

Rel with​

VT​

Concept Name​

VM​ Req Type​ Condition​

Value Set​

 

 

Parent​

 

 

 

 

Constraint​

1​

 

 

COMPOSITE​BCID 3407 “Purpose of​

1​

M​

 

 

 

 

 

Reference to Object”​

 

 

 

2​

>​

HAS​

CODE​

EV (121144, DCM,​

1​

MC​ IFF Row 1​

Root node concept​

 

 

PROPERTIES​

"Document Title")​

 

references an​ of referenced SR​

 

 

 

 

 

 

SR object​

object​

3​

>​

 

INCLUDE​

DTID 3010 “Log Entry​

1​

U​

 

 

 

 

 

Qualifiers”​

 

 

 

- Standard -​

Page 168​

DICOM PS3.16 2020a - Content Mapping Resource​

TID 3104 Consumables​

TheConsumablesTemplateallowsrecordingofdevices(e.g.,cathetersorstents),drugs,orcontrastagentsaccessedinaprocedure.​ This Content Item is directed towards inventory control and billing. The actual clinical use of the particular consumable is recorded​ using TID 3106 “Drugs/Contrast Administered” or TID 3107 “Device Used”.​

This Template allows recording both consumable retrieval from, and return to, inventory or stock, and disposal of used material. The​ quantity involved in each recorded transaction may be specified.​

Type:​

Extensible​

Order:​

Significant​

Root:​

No​

Table TID 3104. Consumables​

 

NL​

Rel with Parent​ VT​

Concept Name​

VM​ ReqType​Condition​ Value Set​

 

 

 

 

 

 

 

Constraint​

1​

 

 

CODE​

DCID 3408 “Actions With​

1​

M​

Vendor or local​

 

 

 

 

Consumables”​

 

 

bar coded values​

2​

>​

HAS​

TEXT​

DCID 3426 “Consumables​

1-n​

U​

 

 

 

PROPERTIES​

 

Parameters”​

 

 

 

3​

>​

HAS​

NUM​

EV (121146, DCM, "Quantity​

1​

U​

 

 

 

PROPERTIES​

 

of Material")​

 

 

 

4​

>​

HAS​

CODE​

EV (121147, DCM, "Billing​

1​

U​

local billing codes​

 

 

PROPERTIES​

 

Code")​

 

 

 

5​

>​

 

INCLUDE​

DTID 3010 “Log Entry​

1​

U​

 

 

 

 

 

Qualifiers”​

 

 

 

TID 3105 Lesion Identification and Properties​

The Lesion Identification and Properties Template allows recording the identification of each lesion addressed in a procedure. The​ lesion identifier may be used to relate diagnostic or therapeutic actions with their target lesion (see Row 4 in TID 3010 “Log Entry​ Qualifiers”). This Content Item may include the initial visually estimated measurements of stenosis or TIMI flow; measured values​ from a quantitative measurement report may be referenced indirectly (through TID 3103 “Referenced Object”), or by quotation (TID​ 3109“Measurements”).Subsequent(e.g.,post-intervention)stenosismeasurementsmaybeencodedusingTID3109“Measurements”,​ with the Lesion Identifier conveyed through its subsidiary TID 3010 “Log Entry Qualifiers” Template.​

Type:​

Extensible​

Order:​

Significant​

Root:​

No​

Table TID 3105. Lesion Identification and Properties​

 

NL​

Rel with Parent​

VT​

Concept Name​

VM​

Req​ Condition​Value Set Constraint​

 

 

 

 

 

 

Type​

 

1​

 

 

TEXT​

EV (121151, DCM, "Lesion​

1​

M​

Up to 3 numeric​

 

 

 

 

Identifier")​

 

 

characters​

2​

>​

HAS​

CODE​

EV (363698007, SCT,​

1​

M​

DCID 3604 “Arterial​

 

 

PROPERTIES​

 

"Finding Site")​

 

 

Lesion Locations”​

3​

>>​

HAS CONCEPT​ CODE​

EV (106233006, SCT,​

1​

U​

DCID 3019​

 

 

MOD​

 

"Topographical modifier")​

 

 

“Cardiovascular​

 

 

 

 

 

 

 

Anatomic Location​

 

 

 

 

 

 

 

Modifiers”​

4​

>​

HAS​

CODE​

EV (121153, DCM, "Lesion​

1​

U​

DCID3418“LesionRisk”​

 

 

PROPERTIES​

 

Risk")​

 

 

 

- Standard -​

 

 

 

DICOM PS3.16 2020a - Content Mapping Resource​

Page 169​

 

NL​

Rel with Parent​

VT​

Concept Name​

VM​

Req​ Condition​Value Set Constraint​

 

 

 

 

 

 

Type​

 

5​

>​

HAS​

NUM​

EV(408715008,SCT,"Lumen​ 1​

U​

UNITS=EV(%,UCUM,​

 

 

PROPERTIES​

 

Diameter Stenosis")​

 

 

"%")​

6​

>>​

HAS CONCEPT​ CODE​

EV (129085009, SCT,​

1​

M​

EV (128955008, SCT,​

 

 

MOD​

 

"Catheterization Procedure​

 

 

"Baseline Phase")​

 

 

 

 

Phase")​

 

 

 

7​

>>​

HAS CONCEPT​ CODE​

EV (121401, DCM,​

1​

U​

DCID 3745 “Calculation​

 

 

MOD​

 

"Derivation")​

 

 

Method”​

8​

>​

HAS​

CODE​

EV (122109, DCM, "Baseline​ 1​

UC​ IFF Row 2​DCID 3713 “TIMI Flow​

 

 

PROPERTIES​

 

TIMI Flow")​

 

 

specifiesa​Characteristics”​

 

 

 

 

 

 

 

coronary​

 

 

 

 

 

 

 

artery​

9​

>​

HAS​

CODE​

EV (122131, DCM, "Degree​

1​

U​

DCID 3714 “Thrombus”​

 

 

PROPERTIES​

 

of Thrombus")​

 

 

 

10​

>​

HAS​

CODE​

EV(129737002,SCT,"Lesion​ 1​

U​

DCID 3715 “Lesion​

 

 

PROPERTIES​

 

Margin Characteristics")​

 

 

Margin”​

11​

>​

HAS​

CODE​

EV (122134, DCM, "Vessel​

1-n​

U​

DCID 3712 “Vessel​

 

 

PROPERTIES​

 

Morphology")​

 

 

Descriptors”​

12​

>​

HAS​

CODE​

EV (122132, DCM, "Severity​

1​

U​

DCID 3716 “Severity”​

 

 

PROPERTIES​

 

of Calcification")​

 

 

 

13​

>​

HAS​

IMAGE​

DT (121080, DCM, "Best​

1​

U​

 

 

 

PROPERTIES​

 

illustration of finding")​

 

 

 

14​

>​

 

INCLUDE​ DTID 3010 “Log Entry​

1​

U​

 

 

 

 

 

Qualifiers”​

 

 

 

Content Item Descriptions​

 

 

 

 

 

Row 1​

Lesion Identifier is specified as a numeric text string in order to facilitate transcoding to DICOM Attribute​

 

 

(0018,3105) Lesion Number and to formats for outcomes registries, such as the ACC National Cardiovascular​

 

 

Data Registry™.​

 

 

 

 

TID 3106 Drugs/Contrast Administered​

The Drugs/Contrast Administered Template allows the recording of the start or end of that type of event, together with its parameters.​ If start and end are represented by a single log entry (e.g., for an injection), the concept name "Drug/contrast administered" shall be​ used.​

Type:​

Extensible​

Order:​

Significant​

Root:​

No​

 

Table TID 3106. Drugs/Contrast Administered​

 

NL​ Rel with Parent​ VT​

Concept Name​

VM​

Req​ Condition​ Value Set​

 

 

 

 

Type​

Constraint​

1​

CODE​

DCID 3409 “Administration of​

1​

M​

BCID 10​

 

 

Drugs/Contrast”​

 

 

“Interventional Drug”​

or​

BCID 12​ “Radiographic​ Contrast Agent”​

- Standard -​

Page 170​

 

DICOM PS3.16 2020a - Content Mapping Resource​

 

 

NL​ Rel with Parent​ VT​

Concept Name​

VM​

Req​ Condition​ Value Set​

 

 

 

 

 

 

Type​

Constraint​

2​

>​

HAS​

TEXT​

EV(121145,DCM,"Description​

1​

U​

 

 

 

PROPERTIES​

 

of Material")​

 

 

 

3​

>​

HAS​

CODE​

EV (410675002, SCT, "Route​

1​

U​

BCID 11 “Route of​

 

 

PROPERTIES​

 

of administration")​

 

 

Administration”​

4​

>​

HAS​

NUM​

DCID 3410 “Numeric​

1-n​

U​

 

 

 

PROPERTIES​

 

Parameters of Drugs/Contrast”​

 

 

 

5​

>​

HAS​

PNAME​

EV (121152, DCM, "Person​

1​

U​

 

 

 

PROPERTIES​

 

administering drug/contrast")​

 

 

 

6​

>​

 

INCLUDE​ DTID 3010 “Log Entry​

1​

U​

 

 

 

 

 

Qualifiers”​

 

 

 

TID 3107 Device Used​

The Device Used Template allows recording of the use of interventional diagnostic and therapeutic devices.​

The identification of one device used to deploy another device (e.g., a balloon catheter to deploy a stent) may be described with two​ entries,withoneidentifiedasadeploymentdeviceintheConceptModifierofRow6ofthisTemplate,andlinkedbythesameProcedure​ Action ID in the Log Entry Qualifiers of the included TID 3010 “Log Entry Qualifiers”.​

Type:​

Extensible​

Order:​

Significant​

Root:​

No​

Table TID 3107. Device Used​

 

NL​

Rel with Parent​ VT​

Concept Name​

VM​

Req​ Condition​Value Set Constraint​

 

 

 

 

 

 

Type​

 

1​

 

 

CODE​

DCID 3422 “Device Use​

1​

M​

BCID 3429​

 

 

 

 

Actions”​

 

 

“Catheterization​

 

 

 

 

 

 

 

Devices”​

2​

>​

HAS​

CODE​

EV (121150, DCM, "Device​

1-n​

U​

Vendor or local bar​

 

 

PROPERTIES​

 

Code")​

 

 

coded values​

3​

>​

HAS​

TEXT​

EV (121145, DCM,​

1​

U​

 

 

 

PROPERTIES​

 

"Description of Material")​

 

 

 

4​

>​

HAS​

NUM​

DCID 3423 “Numeric Device​ 1-n​

U​

 

 

 

PROPERTIES​

 

Characteristics”​

 

 

 

5​

>​

HAS​

CODE​

EV (363704007, SCT,​

1​

U​

BCID 3630​

 

 

PROPERTIES​

 

"Procedure site")​

 

 

“Cardiovascular​

 

 

 

 

 

 

 

Anatomic Locations”​

6​

>​

HAS CONCEPT​ CODE​

EV (363703001, SCT, "Has​

1​

U​

DT (121155, DCM,​

 

 

MOD​

 

Intent")​

 

 

"Deployment")​

7​

>​

 

INCLUDE​ DTID 3010 “Log Entry​

1​

U​

 

 

 

 

 

Qualifiers”​

 

 

 

TID 3108 Intervention​

TheInterventionTemplateallowsrecordingofinterventions,includingatherectomy,angioplasty,stentplacement,brachytherapy,etc.​ The record may include reference to an image that documents the intervention.​

Type:​

Extensible​

Order:​

Significant​

Root:​

No​

- Standard -​

Источник: https://studfile.net/preview/14585769/