DICOM PS3.16 2020a - Content Mapping Resource |
Page 161 |
|||
Root: |
|
|
No |
|
|
|
|
|
|
Table TID 2101. Macular Grid Thickness and Volume Measurement |
|||||
|
NL RelwithParent VT |
Concept Name |
VM |
ReqConditionValue Set Constraint |
|||
|
|
|
|
|
|
Type |
|
1 |
|
|
CONTAINEREV (121070, DCM, "Findings") |
1 |
M |
|
|
2 |
> |
HASCONCEPTCODE |
EV (363698007, SCT, "Finding 1 |
M |
EV (81745001, SCT, |
||
|
|
MOD |
|
Site") |
|
|
"Eye") |
3 |
>> |
HASCONCEPTCODE |
EV (272741003, SCT, |
1 |
M |
$Laterality |
|
|
|
MOD |
|
"Laterality") |
|
|
|
4 |
> |
CONTAINS |
NUM |
EV (57108-3, LN, "Macular |
1 |
M |
UNITS=EV(um,UCUM, |
|
|
|
|
Grid.Center Point Thickness") |
|
|
"micrometer") |
5 |
> |
CONTAINS |
NUM |
EV (57109-1, LN, "Macular |
1 |
M |
UNITS=EV(um,UCUM, |
|
|
|
|
Grid.Center Subfield |
|
|
"micrometer") |
|
|
|
|
Thickness") |
|
|
|
6 |
> |
CONTAINS |
NUM |
EV (57110-9, LN, "Macular |
1 |
M |
UNITS=EV(um,UCUM, |
|
|
|
|
Grid.Inner Superior Subfield |
|
|
"micrometer") |
|
|
|
|
Thickness") |
|
|
|
7 |
> |
CONTAINS |
NUM |
EV (57111-7, LN, "Macular |
1 |
M |
UNITS=EV(um,UCUM, |
|
|
|
|
Grid.Inner Nasal Subfield |
|
|
"micrometer") |
|
|
|
|
Thickness") |
|
|
|
8 |
> |
CONTAINS |
NUM |
EV (57112-5, LN, "Macular |
1 |
M |
UNITS=EV(um,UCUM, |
|
|
|
|
Grid.Inner Inferior Subfield |
|
|
"micrometer") |
|
|
|
|
Thickness") |
|
|
|
9 |
> |
CONTAINS |
NUM |
EV (57113-3, LN, "Macular |
1 |
M |
UNITS=EV(um,UCUM, |
|
|
|
|
Grid.Inner Temporal Subfield |
|
|
"micrometer") |
|
|
|
|
Thickness") |
|
|
|
10 |
> |
CONTAINS |
NUM |
EV (57114-1, LN, "Macular |
1 |
M |
UNITS=EV(um,UCUM, |
|
|
|
|
Grid.Outer Superior Subfield |
|
|
"micrometer") |
|
|
|
|
Thickness") |
|
|
|
11 |
> |
CONTAINS |
NUM |
EV (57115-8, LN, "Macular |
1 |
M |
UNITS=EV(um,UCUM, |
|
|
|
|
Grid.Outer Nasal Subfield |
|
|
"micrometer") |
|
|
|
|
Thickness") |
|
|
|
12 |
> |
CONTAINS |
NUM |
EV (57116-6, LN, "Macular |
1 |
M |
UNITS=EV(um,UCUM, |
|
|
|
|
Grid.Outer Inferior Subfield |
|
|
"micrometer") |
|
|
|
|
Thickness") |
|
|
|
13 |
> |
CONTAINS |
NUM |
EV (57117-4, LN, "Macular |
1 |
M |
UNITS=EV(um,UCUM, |
|
|
|
|
Grid.Outer Temporal Subfield |
|
|
"micrometer") |
|
|
|
|
Thickness") |
|
|
|
14 |
> |
CONTAINS |
NUM |
EV (57118-2, LN, "Macular |
1 |
M |
UNITS = EV (mm3, |
|
|
|
|
Grid.Total Volume") |
|
|
UCUM, "mm3") |
15 |
> |
CONTAINS |
NUM |
EV (111691, DCM, "Number of 1 |
M |
UNITS = EV ({images}, |
|
|
|
|
|
Images Used for Macular |
|
|
UCUM, "images") |
|
|
|
|
Measurements") |
|
|
|
16 |
> |
CONTAINS |
NUM |
EV (111692, DCM, "Number of 1 |
M |
UNITS = EV ({samples}, |
|
|
|
|
|
Samples Used per Image") |
|
|
UCUM, "samples") |
17 |
> |
CONTAINS |
NUM |
EV (111693, DCM, "Analysis |
1 |
M |
UNITS = EV ({0:100}, |
|
|
|
|
Quality Rating") |
|
|
UCUM, "range:0:100") |
Value = 0 - 100
- Standard -
Page 162 |
|
DICOM PS3.16 2020a - Content Mapping Resource |
|
||||
|
NL RelwithParent VT |
Concept Name |
VM |
ReqConditionValue Set Constraint |
|||
|
|
|
|
|
|
Type |
|
18 |
>> |
HAS OBS |
INCLUDE |
DTID 2102 “Quality Rating |
1 |
M |
|
|
|
CONTEXT |
|
Identification” |
|
|
|
19 |
> |
CONTAINS |
NUM |
EV (111694, DCM, "Image Set 1 |
M |
UNITS = EV ({0:100}, |
|
|
|
|
|
Quality Rating") |
|
|
UCUM, "range:0:100") |
|
|
|
|
|
|
|
Value = 0 - 100 |
20 |
>> |
HAS OBS |
INCLUDE |
DTID 2102 “Quality Rating |
1 |
M |
|
|
|
CONTEXT |
|
Identification” |
|
|
|
21 |
> |
CONTAINS |
NUM |
EV (111029, DCM, "Image |
1-n |
U |
UNITS = EV ({0:100}, |
|
|
|
|
Quality Rating") |
|
|
UCUM, "range:0:100") |
|
|
|
|
|
|
|
Value = 0 - 100 |
22 |
>> |
INFERRED |
IMAGE |
|
1 |
M |
|
|
|
FROM |
|
|
|
|
|
23 |
>> |
HAS OBS |
INCLUDE |
DTID 2102 “Quality Rating |
1 |
M |
|
|
|
CONTEXT |
|
Identification” |
|
|
|
24 |
> |
CONTAINS |
CODE |
EV (111696, DCM, "Visual |
1 |
U |
DCID 4220 “Visual |
|
|
|
|
Fixation Quality During |
|
|
Fixation Quality During |
|
|
|
|
Acquisition") |
|
|
Acquisition” |
25 |
>> |
HASCONCEPTCODE |
EV (111697, DCM, "Visual |
1-n |
U |
DCID 4221 “Visual |
|
|
|
MOD |
|
Fixation Quality Problem") |
|
|
FixationQualityProblem” |
26 |
> |
CONTAINS |
CODE |
EV(111698,DCM,"Ophthalmic1-n |
U |
DCID 4222 “Ophthalmic |
|
|
|
|
|
Macular Grid Problem") |
|
|
Macular Grid Problem” |
27 |
> |
CONTAINS |
TEXT |
EV(121106,DCM,"Comment") 1 |
U |
|
|
Content Item Descriptions |
|
|
|
|
|
||
Row 22 |
|
No purpose of reference is specified. |
|
|
|||
TID 2102 Quality Rating Identification
This Template specifies the algorithm (and parameters) used to create a quality rating for an image or image set.
It is expected that the identified algorithm will create a consistent quality rating when analyzing a given image. If the algorithm allows change to its parameters that would alter the quality rating created, the specific parameters used should be specified.
Type: |
Non-Extensible |
Order: |
Significant |
Root: |
No |
Table TID 2102. Quality Rating Identification
NL Rel with |
VT |
Concept Name |
VM |
Req TypeConditionValue Set |
Parent |
|
|
|
Constraint |
1 |
TEXT |
EV (111001, DCM, "Algorithm |
1 |
M |
|
|
Name") |
|
|
2 |
TEXT |
EV (111003, DCM, "Algorithm |
1 |
M |
|
|
Version") |
|
|
3 |
TEXT |
EV (122405, DCM, "Algorithm |
1 |
M |
|
|
Manufacturer") |
|
|
4 |
TEXT |
EV (111002, DCM, "Algorithm |
1-n |
U |
|
|
Parameters") |
|
|
- Standard -
DICOM PS3.16 2020a - Content Mapping Resource |
Page 163 |
Procedure Log IOD Templates
TID 3001 Procedure Log
The Procedure Log Template is intended for the representation of reports or logs of time-stamped events occurring during an image- guided interventional or other procedure.
This Template does not require a particular ordering of the subsidiary Content Items.
Note
1.The Procedure Log IOD (PS3.3) requires ordering by Observation DateTime; thus log entries of different types (i.e., specified by different Rows in the Template) may appear in any order.
2.While this Template is extensible, the Procedure Log IOD forbids Container Content Items subsidiary to the top level Container.
Type: |
Extensible |
Order: |
Non-Significant |
Root: |
Yes |
Table TID 3001. Procedure Log
|
NL |
Rel with Parent |
VT |
Concept Name |
VM |
Req ConditionValue Set |
||
|
|
|
|
|
|
|
Type |
Constraint |
1 |
|
|
CONTAINER |
DCID 3400 “Procedure Log |
1 |
M |
Root node |
|
|
|
|
|
|
Titles” |
|
|
|
2 |
> |
|
INCLUDE |
DTID 1002 “Observer Context” |
1-n |
M |
|
|
3 |
> |
|
INCLUDE |
DTID3601“ProcedureContext” |
1 |
M |
|
|
4 |
> |
HAS ACQ |
TEXT |
EV (121121, DCM, "Room |
1 |
U |
|
|
|
|
CONTEXT |
|
|
identification") |
|
|
|
5 |
> |
HAS ACQ |
TEXT |
EV (121122, DCM, "Equipment |
1-n |
U |
|
|
|
|
CONTEXT |
|
|
identification") |
|
|
|
6 |
> |
CONTAINS |
TEXT |
DCID 3401 “Types of Log |
1-n |
U |
|
|
|
|
|
|
|
Notes” |
|
|
|
7 |
>> |
|
INCLUDE |
DTID 3010 “Log Entry |
1 |
U |
|
|
|
|
|
|
|
Qualifiers” |
|
|
|
8 |
> |
CONTAINS |
CODE |
EV (121123, DCM, "Patient |
1-n |
U |
DCID 3402 |
|
|
|
|
|
|
Status or Event") |
|
|
“Patient |
|
|
|
|
|
|
|
|
Status and |
|
|
|
|
|
|
|
|
Events” |
9 |
>> |
|
INCLUDE |
DTID 3010 “Log Entry |
1 |
U |
|
|
|
|
|
|
|
Qualifiers” |
|
|
|
10 |
> |
CONTAINS |
PNAME |
DCID 3404 “Staff Actions” |
1-n |
U |
|
|
11 |
>> |
|
INCLUDE |
DTID 3010 “Log Entry |
1 |
U |
|
|
|
|
|
|
|
Qualifiers” |
|
|
|
12 |
> |
CONTAINS |
TEXT |
DCID3427 “Equipment Events” |
1-n |
U |
Equipment |
|
|
|
|
|
|
|
|
|
identifier |
13 |
>> |
|
INCLUDE |
DTID 3010 “Log Entry |
1 |
U |
|
|
|
|
|
|
|
Qualifiers” |
|
|
|
14 |
> |
CONTAINS |
INCLUDE |
DTID 3100 “Procedure Action” |
1-n |
U |
|
|
15 |
> |
CONTAINS |
INCLUDE |
DTID 3101 “Image Acquisition” |
1-n |
U |
|
|
16 |
> |
CONTAINS |
INCLUDE |
DTID 3102 “Waveform |
1-n |
U |
|
|
|
|
|
|
|
Acquisition” |
|
|
|
- Standard -
Page 164 |
|
|
DICOM PS3.16 2020a - Content Mapping Resource |
|
|
|||
|
NL |
Rel with Parent |
VT |
Concept Name |
VM |
Req ConditionValue Set |
||
|
|
|
|
|
|
|
Type |
Constraint |
17 |
> |
CONTAINS |
INCLUDE |
DTID3103“ReferencedObject” |
1-n |
U |
|
|
18 |
> |
CONTAINS |
INCLUDE |
DTID 3104 “Consumables” |
1-n |
U |
|
|
19 |
> |
CONTAINS |
INCLUDE |
DTID3105“LesionIdentification |
1-n |
U |
|
|
|
|
|
|
|
and Properties” |
|
|
|
20 |
> |
CONTAINS |
INCLUDE |
DTID 3106 “Drugs/Contrast |
1-n |
U |
|
|
|
|
|
|
|
Administered” |
|
|
|
21 |
> |
CONTAINS |
INCLUDE |
DTID 3107 “Device Used” |
1-n |
U |
|
|
22 |
> |
CONTAINS |
INCLUDE |
DTID 3108 “Intervention” |
1-n |
U |
|
|
23 |
> |
CONTAINS |
CODE |
EV (116224001, SCT, |
1-n |
U |
DCID 3413 |
|
|
|
|
|
|
"Complication of Procedure") |
|
|
“Adverse |
|
|
|
|
|
|
|
|
Outcomes” |
24 |
>> |
|
INCLUDE |
DTID 3010 “Log Entry |
1 |
U |
|
|
|
|
|
|
|
Qualifiers” |
|
|
|
25 |
> |
CONTAINS |
INCLUDE |
DTID 3109 “Measurements” |
1-n |
U |
|
|
26 |
> |
CONTAINS |
INCLUDE |
DTID 3110 “Impressions or |
1-n |
U |
|
|
|
|
|
|
|
Findings” |
|
|
|
27 |
> |
CONTAINS |
INCLUDE |
DTID 3111 “Percutaneous |
1-n |
U |
|
|
|
|
|
|
|
Entry” |
|
|
|
28 |
> |
CONTAINS |
INCLUDE |
DTID 3112 “Specimen |
1-n |
U |
|
|
|
|
|
|
|
Obtained” |
|
|
|
29 |
> |
CONTAINS |
INCLUDE |
DTID 3113 “Patient Support” |
1-n |
U |
|
|
30 |
> |
CONTAINS |
INCLUDE |
DTID 3114 “Patient |
1-n |
U |
|
|
|
|
|
|
|
Assessment” |
|
|
|
31 |
> |
CONTAINS |
INCLUDE |
DTID 3115 “ECG ST |
1-n |
U |
|
|
|
|
|
|
|
Assessment” |
|
|
|
Content Item Descriptions |
|
|
|
|
|
|
||
Row 2 |
|
Includes TID 1002 “Observer Context”, which shall be used to record the identity of the person responsible for |
||||||
|
|
recording the log, as well as all other participants in the procedure, even though these personnel may not |
||||||
|
|
technically be "observers" of the Procedure Log. As participants in the procedure, they are potential sources for |
||||||
|
|
eventsandobservationsrecordedintheLog.TID1002“ObserverContext”allowsthespecificationoftheperson's |
||||||
|
|
role in the organization (e.g., physician, nurse), as well as the role in the procedure (e.g., circulating, performing, |
||||||
|
|
etc.). |
|
|
|
|
|
|
Row 5 |
|
Shall be used to record the identity of the major equipment used in the procedure. |
|
|||||
Row 6 |
|
May be used to record any event not covered by a specific log entry Template. |
|
|||||
TID 3010 Log Entry Qualifiers
The Log Entry Qualifiers Template provides a common means for adding additional description to a procedure log Content Item. It allows identification of a source for the procedure log entry (other than the recording observer for the log as a whole), a free text comment, a link to a particular Procedure Action item, a link to a particular lesion, or the date/time of recording (if different than the time of the event occurrence recorded in the Observation DateTime of the parent Content Item).
Type: |
Extensible |
Order: |
Significant |
Root: |
No |
- Standard -
DICOM PS3.16 2020a - Content Mapping Resource Page 165
Table TID 3010. Log Entry Qualifiers
NL |
Rel with Parent |
VT |
Concept Name |
VM |
Req Condition Value Set |
|
|
|
|
|
|
Type |
Constraint |
1 |
|
INCLUDE |
DTID 1000 “Quotation” |
1 |
U |
|
2 |
HAS PROPERTIES TEXT |
EV (121106, DCM, |
1 |
U |
|
|
|
|
|
"Comment") |
|
|
|
3 |
HAS OBS CONTEXTTEXT |
EV (121124, DCM, |
1-n |
U |
|
|
|
|
|
"Procedure Action ID") |
|
|
|
4 |
HAS OBS CONTEXTTEXT |
EV (121151, DCM, "Lesion |
1-n |
U |
Upto3numeric |
|
|
|
|
Identifier") |
|
|
characters |
5 |
HAS OBS CONTEXTDATETIME |
EV (121125, DCM, |
1 |
U |
|
|
|
|
|
"DateTime of Recording of |
|
|
|
|
|
|
Log Entry") |
|
|
|
6 |
INFERRED FROM |
IMAGE |
|
1-n |
U |
|
7 |
INFERRED FROM |
WAVEFORM |
|
1-n |
U |
|
8 |
INFERRED FROM |
COMPOSITE |
|
1-n |
U |
|
9 |
HAS OBS CONTEXTCODE |
EV (121135, DCM, |
1 |
U |
DCID 3430 |
|
|
|
|
"Observation DateTime |
|
|
“DateTime |
|
|
|
Qualifier") |
|
|
Qualifiers” |
Content Item Descriptions |
|
|
|
|
|
|
Row 3 |
Procedure Action ID allows linking recorded events to a particular action, step, or phase of a procedure. See |
|||||
|
description for TID 3100 “Procedure Action”. |
|
|
|
||
Row 4 |
Lesion Identifier is specified as a numeric text string, and allows linking recorded events to the diagnosis or |
|||||
|
therapy of particular lesion. See description for TID 3105 “Lesion Identification and Properties”. |
|||||
TID 3100 Procedure Action
TheProcedureActionTemplateisintendedfortherecordingofthebeginningorendofprocedurestepsoractionitemsinaprocedure. The level of granularity of the recorded events is not specified, and may vary between institutions, or even be at multiple levels within a single procedure log. There is no requirement for the real-world procedure step or action item recorded with this Template to end before another one begins; there may be overlapping or simultaneous procedure steps or action items.
This log entry Template may be used to record the start or stop of timers.
Other recorded events in the procedure may be linked to a particular step or action item by Procedure Action ID (see TID 3010 “Log Entry Qualifiers”).
Type: |
Extensible |
Order: |
Significant |
Root: |
No |
|
Table TID 3100. Procedure Action |
|
NL Rel with Parent VT |
Concept Name |
VM |
Req |
Condition |
Value Set |
|
|
|
|
|
|
Type |
|
Constraint |
1 |
|
CODE |
DCID3421“ProcedureAction” |
1 |
M |
|
BCID 3405 |
|
|
|
|
|
|
|
“Procedure |
|
|
|
|
|
|
|
Action |
|
|
|
|
|
|
|
Values” |
2 |
> HAS |
TEXT |
EV (121124, DCM, |
1 |
M |
|
|
|
PROPERTIES |
|
"Procedure Action ID") |
|
|
|
|
- Standard -