Page 336 |
|
DICOM PS3.16 2020a - Content Mapping Resource |
|
||||
|
NLRel with Parent VT |
Concept Name |
VM Req |
Condition |
Value Set Constraint |
||
|
|
|
|
|
Type |
|
|
14 |
>> |
SELECTED |
IMAGE |
|
1 M |
|
All the row 13 Content |
|
|
FROM |
|
|
|
|
Items in a single |
|
|
|
|
|
|
|
invocation of this |
|
|
|
|
|
|
|
Templateshallreference |
|
|
|
|
|
|
|
the same IMAGE |
15 |
> |
HAS |
INCLUDEDTID 4014 “CAD |
1 MC Shall be present IFF |
$QualityFinding = DCID |
||
|
|
PROPERTIES |
Image Quality” |
|
value of row 1 is |
6135 “Image Quality |
|
|
|
|
|
|
|
(111101, DCM, "ImageFinding” |
|
|
|
|
|
|
|
quality") |
$QualityStandard = |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
DCID 6208 “Colon |
|
|
|
|
|
|
|
Types of Quality Control |
|
|
|
|
|
|
|
Standard” |
Content Item Descriptions |
|
|
|
|
|||
Rendering Intent |
This Content Item constrains the SCP receiving the Colon CAD SR IOD in its use of the contents of this |
||||||
|
|
|
Template and its Target Content Items. Colon CAD devices may opt to use data marked "Not for |
||||
|
|
|
Presentation" or "Presentation Optional" as input to subsequent colon CAD processing steps. Refer to |
||||
|
|
|
Section O.2 “Structured Reporting Storage SOP Class SCU and SCP Behavior” in PS3.4. |
||||
CAD Operating Point |
AdditionalinformationtousewhenRenderingIntentis"PresentationalOptional".ACADOperatingPoint |
||||||
|
|
|
of zero is not sent, and is encoded as a Rendering Intent of "Presentation Required". See Section O.2 |
||||
|
|
|
“Structured Reporting Storage SOP Class SCU and SCP Behavior” in PS3.4 and Section E.4 “CAD |
||||
|
|
|
Operating Point” in PS3.17. |
|
|
|
|
Certainty of Finding |
The certainty of the CAD device that the finding detected and classified by the Single Image Finding |
||||||
|
|
|
CODE specified is in fact that type of finding. |
|
|
||
TID 4128 Colon CAD Descriptors
This Template provides qualitative detail for a Single Image Finding or Composite Feature. It is applied to Colon CAD Composite Feature (TID 4125 “Colon CAD Composite Feature”) and Colon CAD Single Image Finding (TID 4127 “Colon CAD Single Image Finding”).
Type: |
Non-Extensible |
Order: |
Significant |
Root: |
No |
Table TID 4128. Colon CAD Descriptors
NL |
Rel with |
VT |
Concept Name |
VM |
Req Condition Value Set Constraint |
|
|
Parent |
|
|
|
Type |
|
1 |
|
CODE |
EV (116676008, SCT, |
1-n |
U |
DCID6209“ColonMorphology |
|
|
|
"Associated Morphology") |
|
|
Descriptor” |
2 |
|
CODE |
EV (363698007, SCT, |
1 |
U |
DCID 6210 “Location in |
|
|
|
"Finding Site") |
|
|
Intestinal Tract” |
3 |
|
CODE |
EV (111014, DCM, |
1 |
U |
DCID6205“ClockfaceLocation |
|
|
|
"Clockface or region") |
|
|
for Colon” |
- Standard -
|
|
|
DICOM PS3.16 2020a - Content Mapping Resource |
Page 337 |
||
NL Rel with |
VT |
Concept Name |
VM |
Req Condition Value Set Constraint |
||
|
Parent |
|
|
|
Type |
|
4 |
CONTAINS |
INCLUDE DTID 300 “Measurement” |
1-n |
U |
$Measurement = DCID 6212 |
|
|
|
|
|
|
|
“Calculated Value for Colon |
|
|
|
|
|
|
Findings” |
|
|
|
|
|
|
$Derivation = DCID 6140 |
|
|
|
|
|
|
“Calculation Methods” |
|
|
|
|
|
|
$DerivationParameter = EV |
|
|
|
|
|
|
(112032, DCM, "Threshold |
|
|
|
|
|
|
Attenuation Coefficient") |
|
|
|
|
|
|
$DerivationParameterUnits = |
|
|
|
|
|
|
EV ([hnsf'U], UCUM, |
|
|
|
|
|
|
"Hounsfield unit") |
5 |
|
INCLUDE DTID 1400 “Linear |
1-n |
U |
|
|
|
|
|
Measurement” |
|
|
|
6 |
|
INCLUDE DTID 1401 “Area |
1-n |
U |
|
|
|
|
|
Measurement” |
|
|
|
7 |
|
INCLUDE DTID 1402 “Volume |
1-n |
U |
|
|
|
|
|
Measurement” |
|
|
|
8 |
|
INCLUDE DTID 1406 “Three |
1-n |
U |
|
|
|
|
|
Dimensional Linear |
|
|
|
|
|
|
Measurement” |
|
|
|
9 |
|
NUM |
DCID 6141 “Attenuation |
1-n |
U |
UNITS = EV ([hnsf'U], UCUM, |
|
|
|
Coefficient Measurements” |
|
|
"Hounsfield unit") |
10 > |
HAS |
CODE |
EV(112009,DCM,"Typeof |
1 |
U |
DCID 6211 “Colon CAD |
|
PROPERTIES |
Content") |
|
|
Material Description” |
|
Content Item Descriptions |
|
|
|
|
||
Row 3 |
12 o'clock position is the anterior direction of the patient regardless of the positioning with respect to gravity; |
|||||
|
clockwise is from the point of view of an observer located closer to the anus than the finding being observed. |
|||||
TID 4129 Colon CAD Geometry
All geometry Template invocations require specification of either the location of the center of the object, the outline, or both. Geometry isapropertyofsingleimagefindings(seeTID4127“ColonCADSingleImageFinding”)andcompositefeatures(seeTID4125“Colon CAD Composite Feature”).
Type: |
Non-Extensible |
Order: |
Significant |
Root: |
No |
|
Table TID 4129. Colon CAD Geometry |
NL |
Rel with |
VT |
Concept Name |
VM |
Req |
Condition |
Value Set |
|
Parent |
|
|
|
Type |
|
Constraint |
1 |
|
SCOORD |
EV (111010, DCM, |
1 |
MC |
At least one of rows 1,GRAPHIC TYPE = |
|
|
|
|
"Center") |
|
|
3, 4, 6 or 10 shall be {POINT} |
|
|
|
|
|
|
|
present. |
|
2 > |
SELECTEDIMAGE |
|
1 |
M |
|
|
|
|
FROM |
|
|
|
|
|
|
- Standard -
Page 338 |
|
DICOM PS3.16 2020a - Content Mapping Resource |
|
|||||
|
NL |
Rel with |
VT |
Concept Name |
VM |
Req |
Condition |
Value Set |
|
|
Parent |
|
|
|
Type |
|
Constraint |
3 |
|
|
SCOORD3DEV (111010, DCM, |
1 |
MC |
At least one of rows 1,GRAPHIC TYPE = |
||
|
|
|
|
"Center") |
|
|
3, 4, 6 or 10 shall be |
{POINT} |
|
|
|
|
|
|
|
present. |
|
4 |
|
|
SCOORD |
EV (111041, DCM, |
1 |
MC |
At least one of rows 1, |
|
|
|
|
|
"Outline") |
|
|
3, 4, 6 or 10 shall be |
|
|
|
|
|
|
|
|
present. |
|
5 |
> |
SELECTEDIMAGE |
|
1 |
M |
|
|
|
|
|
FROM |
|
|
|
|
|
|
6 |
|
|
SCOORD3DEV (111041, DCM, |
1 |
MC |
At least one of rows 1, |
||
|
|
|
|
"Outline") |
|
|
3, 4, 6 or 10 shall be |
|
|
|
|
|
|
|
|
present. |
|
7 |
|
|
SCOORD |
DCID 6166 “CAD |
1-n |
U |
|
|
|
|
|
|
Geometry Secondary |
|
|
|
|
|
|
|
|
Graphical |
|
|
|
|
|
|
|
|
Representation” |
|
|
|
|
8 |
> |
SELECTEDIMAGE |
|
1 |
M |
|
|
|
|
|
FROM |
|
|
|
|
|
|
9 |
|
|
SCOORD3DDCID 6166 “CAD |
1-n |
U |
|
|
|
|
|
|
|
Geometry Secondary |
|
|
|
|
|
|
|
|
Graphical |
|
|
|
|
|
|
|
|
Representation” |
|
|
|
|
10 |
|
|
IMAGE |
EV (112229, DCM, |
1 |
MC |
At least one of rows 1,Referenced image |
|
|
|
|
|
"Identifying Segment") |
|
|
3, 4, 6 or 10 shall be |
shall be a |
|
|
|
|
|
|
|
present. |
Segmentation and |
|
|
|
|
|
|
|
|
the Content Item |
|
|
|
|
|
|
|
|
shall include |
Referenced Segment Number (0062,000B)
Breast Imaging Report Templates
The Templates that comprise the Breast Imaging Report are interconnected as in Figure A-10.
- Standard -
DICOM PS3.16 2020a - Content Mapping Resource |
Page 339 |
||||||||||||||
TID 4200 |
|
TID 1001 |
|
|
|
|
|
|
|
|
|
|
|
||
Breast Imaging |
|
|
Observation Context |
|
|
|
|
|
|
|
|
|
|
|
|
Report |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
TID 4202 |
|
TID 1002 |
|
|
|
|
|
|
||||
|
|
|
Breast Imaging |
|
|
Observer Context |
|
|
|
|
|
|
|||
|
|
|
Report Narrative |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
TID 1204 |
|
TID 350 |
|
|
|
|
|
|
||||
|
|
|
Language of |
|
References to |
|
|
|
|
|
|
||||
|
|
|
Content Item and |
|
Supporting Evidence |
|
|
|
|
|
|
||||
|
|
|
Descendants |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
TID 4208 |
|
TID 4201 |
|
|
|
|
|
|
||||
|
|
|
Breast Imaging |
|
Breast Imaging |
|
|
|
|
|
|
||||
|
|
|
Report |
|
|
Procedure Reported |
|
|
|
|
|
|
|||
|
|
|
Supplementary Data |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
TID 4203 |
|
|
TID 4207 |
|
|
|
|||
|
|
|
|
|
|
Breast Imaging |
|
|
Breast Imaging |
|
|
|
|||
|
|
|
|
|
|
Assessment |
|
|
|
Pathology Results |
|
|
|
||
|
|
|
|
|
|
TID 4205 |
|
|
TID 4201 |
|
|
|
|||
|
|
|
|
|
|
Breast Composition |
|
|
Breast Imaging |
|
|
|
|||
|
|
|
|
|
|
Section |
|
|
|
Procedure Reported |
|
|
|
||
|
|
|
|
|
|
TID 4204 |
|
|
|
|
TID 4201 |
|
|||
|
|
|
|
|
|
Breast Imaging |
|
|
|
|
Breast Imaging |
|
|||
|
|
|
|
|
|
Report |
|
|
|
|
|
|
|
||
|
|
|
|
|
|
Intervention Section |
|
|
|
|
Procedure Reported |
|
|||
|
|
|
|
|
|
|
|
|
|
|
|
||||
|
|
|
|
|
|
TID 4206 |
|
|
TID 1002 |
|
TID 1009 |
|
|||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Breast Imaging |
|
|
|
|
Subject Context, |
|
|||
|
|
|
|
|
|
Report |
|
|
|
Observer Context |
|
Specimen |
|
||
|
|
|
|
|
|
Finding Section |
|
|
|
|
|
||||
|
|
|
|
|
|
|
|
|
|
|
|
||||
|
|
|
|
|
|
|
|
|
|
|
|
TID 350 |
|
TID 4207 |
|
|
|
|
|
|
|
|
|
|
|
|
|
References to |
|
Pathology |
|
|
|
|
|
|
|
|
|
|
|
|
|
Supporting Evidence |
|
Results |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
TID 4201 |
|
TID 350 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Breast Imaging |
|
References to |
|
|
|
|
|
|
|
|
|
|
|
|
|
Procedure Reported |
|
Supporting Evidence |
|
TID 1402
Volume
Measurement
TID 1401
Area
Measurement
TID 1400
Linear
Measurement
TID 4203 |
TID 4207 |
Breast Imaging
Pathology Results
Assessment
Figure A-10. Breast Imaging Report Template Structure
TID 4200 Breast Imaging Report
This Template forms the content tree that allows a Breast Imaging Report device to describe the results of a radiologist's diagnostic interpretation of Breast Imaging (e.g., X-Ray mammography or breast ultrasound) evidence. This Template, together with its subor- dinate Templates, describes the results for presentation to clinicians, or for consumption by Breast Imaging Report devices for sub- sequent Breast Imaging Reports.
This Template shall be instantiated at the Root node only.
See Figure Q.1-1 “Top Level of Breast Imaging Report Content Tree” in PS3.17.
Type: |
Non-Extensible |
Order: |
Significant |
Root: |
Yes |
|
Table TID 4200. Breast Imaging Report |
NL |
Rel with Parent |
VT |
Concept Name |
VM |
Req ConditionValue Set |
|
|
|
|
|
|
Type |
Constraint |
1 |
|
CONTAINER EV (111400, DCM, "Breast |
1 |
M |
Root node |
|
|
|
|
Imaging Report") |
|
|
|
2 > |
HAS CONCEPT INCLUDE |
DTID 1204 “Language of Content |
1 |
M |
|
|
|
MOD |
|
Item and Descendants” |
|
|
|
- Standard -
Page 340 |
|
DICOM PS3.16 2020a - Content Mapping Resource |
|
|
|||
|
NL |
Rel with Parent |
VT |
Concept Name |
VM |
Req ConditionValue Set |
|
|
|
|
|
|
|
Type |
Constraint |
2a |
> |
HAS OBS |
INCLUDE |
TID 1001 “Observation Context” |
1 |
U |
|
|
|
CONTEXT |
|
|
|
|
|
2b |
> |
CONTAINS |
INCLUDE |
DTID 4209 “Breast Patient |
1 |
U |
|
|
|
|
|
Characteristics” |
|
|
|
3 |
> |
CONTAINS |
INCLUDE |
DTID 4202 “Breast Imaging |
1 |
M |
|
|
|
|
|
Report Narrative” |
|
|
|
4 |
> |
CONTAINS |
INCLUDE |
DTID 4208 “Breast Imaging |
1 |
U |
|
|
|
|
|
Report Supplementary Data” |
|
|
|
TID 4201 Breast Imaging Procedure Reported
A procedure that is reported in a Breast Imaging Report is expressed in this Template. The results of more than one procedure may be included in a single report instance (see TID 4208 “Breast Imaging Report Supplementary Data”).
See Figure Q.1-2 “Breast Imaging Procedure Reported Content Tree” in PS3.17. |
|
Type: |
Non-Extensible |
Order: |
Significant |
Root: |
No |
Table TID 4201. Breast Imaging Procedure Reported
|
NL |
Rel with Parent |
VT |
Concept Name |
VM |
Req Condition Value Set Constraint |
||
|
|
|
|
|
|
Type |
|
|
1 |
|
|
CODE |
EV (121058, DCM, |
1 |
M |
BCID 6050 “Breast |
|
|
|
|
|
"Procedure reported") |
|
|
Procedure Reported” |
|
2 |
> |
HAS CONCEPT CODE |
EV (111464, DCM, |
1-n |
U |
DCID |
6058 “Procedure |
|
|
|
MOD |
|
"Procedure Modifier") |
|
|
Modifiers for Breast” |
|
3 |
> |
HAS CONCEPT CODE |
EV (272741003, SCT, |
1 |
M |
DCID |
6022 “Side” |
|
|
|
MOD |
|
"Laterality") |
|
|
|
|
4 |
> |
HAS |
CODE |
EV (111401, DCM, |
1 |
U |
DCID |
6051 “Breast |
|
|
PROPERTIES |
|
"Reason for procedure") |
|
|
Procedure Reason” |
|
5 |
>> |
HAS CONCEPT CODE |
EV (118578006, SCT, |
1 |
U |
DCID |
12102 “Temporal |
|
|
|
MOD |
|
"Relative time") |
|
|
Periods Relating to |
|
|
|
|
|
|
|
|
Procedure or Therapy” |
|
6 |
>> |
HAS CONCEPT CODE |
EV (111402, DCM, |
1-n |
UC IFF row 4DCID |
6055 “Breast Clinical |
||
|
|
MOD |
|
"Clinical Finding") |
|
value is |
Finding or Indicated |
|
|
|
|
|
|
|
"Clinical |
Problem” |
|
|
|
|
|
|
|
Finding" |
Breast Clinical Finding or |
|
|
|
|
|
|
|
|
||
|
|
|
|
|
|
|
Indicated Problem |
|
7 |
>>> |
HAS |
CODE |
EV (272741003, SCT, |
1 |
U |
DCID |
6022 “Side” |
|
|
PROPERTIES |
|
"Laterality") |
|
|
|
|
8 |
> |
HAS |
DATE |
EV (111060, DCM, "Study |
1 |
U |
|
|
|
|
PROPERTIES |
|
Date") |
|
|
|
|
Content Item Descriptions |
|
|
|
|
|
|
||
Row 5 "Relative time" |
This Content Item indicates whether the value of "Reason for procedure" (row 4) is modified |
|||||||
|
|
|
with "pre-" or "follow-up". |
|
|
|
|
|
- Standard -